Please use this identifier to cite or link to this item:
https://irju.jdvu.ac.in/jspui/handle/123456789/10778Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | Sarkar, Sourav | - |
| dc.contributor.author | Samaddar, Koustav | - |
| dc.date.accessioned | 2026-11-03T11:09:27Z | - |
| dc.date.available | 2026-11-03T11:09:27Z | - |
| dc.date.issued | 2024 | - |
| dc.date.submitted | 2024 | - |
| dc.identifier.other | DC5403 | - |
| dc.identifier.uri | https://irju.jdvu.ac.in/jspui/handle/123456789/10778 | - |
| dc.description.abstract | This work describes synthesizing porous nitrogen-doped reduced graphene oxide (N-rGO) via hydrothermal synthesis and it's application as non- enzymatic glucose sensor . Before that, graphene oxide (GO) was prepared using a modified version of Hummer's process. The crystallinity and phase have been verified with an XRD device. Morphological analysis using FESEM images confirms the porous nature. Conversely, comparisons of their UV-vis have been done to help determine the band gaps between GO and rGO. In this project, electrical (resistive) biosensor for glucose monitoring has been experienced. A comparison study of different layers, enzymatic interaction and their out has been carried for the rGO based devices. Here, alpha- glucose has been tested with the biosensor. After a layer-dependent experiment, it can be expressed from the I-V analysis 1layer rGO device has shown a better response than GOx+rGO-coated all devices.1L rGO-coated device also gives better response than 1L GOx+rGO and from LOD curve it can be clearly stated that 1 layer rGO coated device has better sensibility in all aspect. | en_US |
| dc.format.extent | [92]p. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | Jadavpur University, Kolkata, West Bengal | en_US |
| dc.subject | Nanomaterials | en_US |
| dc.subject | Biosensors | en_US |
| dc.subject | Reduced Graphene Oxide | en_US |
| dc.subject | Nitrogen-Doped Graphene | en_US |
| dc.title | Study of nitrogen doped reduced graphene oxide (rGO) for its potential application as a Glucose sensor | en_US |
| dc.type | Text | en_US |
| dc.department | Jadavpur University. School of Materials Science and Nanotechnology | en_US |
| Appears in Collections: | Dissertations | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| M.Tech (School of Material Science and Nanotechnology) Kaustav Samaddar.pdf | 3.6 MB | Adobe PDF | View/Open |
Items in IR@JU are protected by copyright, with all rights reserved, unless otherwise indicated.